Electrical

  • Aux power 12VDC, 600mA max
  • Seven hour standby at 400mAaux load with four amp hour battery
  • 16.5VAC/25VA transformer
  • Alarm output 12VDC, 2.0A max
  • For UL installations, combined aux and alarm output cannot exceed 700mA

Output Control

  • Supports multiple output devices, one 4204 and two triggers

Zones

  • Six hardwired zones
  • Selectable response: 10msec, 350msec, 750msec
  • 16 selectable zone types plus one configurable zone type
  • Programmable swinger suppression

Expansion Devices

  • 4204 – Up to four relays – 15mA standby

  (each active relay draws an additional 40mA)

Agency Listings

  • UL Residential Fire, Burglary and CSFM
  • ETL Residential Fire, Burglary

Smoke Detectors

  • Supports four-wire smoke detectors

Description

Honeywell-ADEMCO VISTA-10P Security Control Panel

Honeywell-ADEMCO’s feature-rich VISTA-10P is suited for a wide range of smaller applications. The six-zone panel can reduce service call costs thanks to user-friendly features that make operation easier than ever. In addition, it features wireless expansion capabilities and ADEMCO’s signature flexibility.

Features

  • Six hardwired zones on board
  • 16 wireless expansion zones totaling 2 protection zones
  • Eight independent keyfob zones allow two wireless keys to be programmed without using any of the 22 zones
  • 32 Event log
  • 16 user codes
  • One configurable zone type allows installers to create their own custom zone type
  • Two on-board triggers
  • Four output devices using a 4204 relay module
  • Flexible function keys allow single button arming
  • One programmable macro key
  • Viewable on system keypad display
    – Exit countdown
    – Time and date*
    – Event log*
  • Two schedules
    – Can activate relays on programmed times or on events
    – Latchkey reports to a pager
    – “User Access” time windows
  • Chime by zone
  • 4286 Phone Module allows system control from any touchtone phone
  • Four output devices with multiple actions per device
    – Turn lights on when system disarms with a 4204 Relay
    – Flash same lights when system is in alarm using a 4204 Relay

* with alpha Keypad