SPECIFICATIONS
Electrical
- Aux. power 12VDC, 600mA maximum
- Seven hour standby at 400mA aux. load with four amp hour battery
- 16.5VAC/25VA transformer
- Alarm output 12VDC, 2.0 amps max.
– For UL installations, combined aux. and alarm output cannot exceed 700mA
Output Control
- Supports up to four relay boards (up to 16 relays)
- Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices
Zones
- Eight hardwired zones (15 with zone doubling)
- Selectable response 10msec, 350msec, 750msec
- Assignable to any partition
- 20 selectable zone types plus four configurable zone types
- Programmable swinger suppression
Agency Listings
- UL Residential Fire, Burglary and CSFM Smoke Detectors
- Supports up to 16 two-wire smoke detectors
- Supports four-wire smoke detectors
Description
Honeywell-ADEMCO VISTA-20P Security Control Panel
The high capacity, feature-rich VISTA-20P by Honeywell-ADEMCO delivers with up to 48 zones of protection, Internet uploading/downloading, graphic keypad support and dual partitions.
VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. In addition, the VISTA-20P, used with an Alarmnet internet or digital communicator can be installed in premises without TELCO lines with no sacrifice in functionality.
The panel’s installation advantages, innovative end-user benefits and robust system capacity make the VISTA-20P an ideal choice for feature-driven small-to-medium-sized installations.
Design Features
- IP alarm reporting and uploading/downloading capability for Internet and Intranet use via 7845i, 7845i-ENT, 7845GSM or 7845I-GSM
- Supports four graphic touchscreen keypads
- Wireless keys can be programmed without using zones
- Eight on-board hardwired zones standard (15 when Zone Doubling feature is used)
– 40 hardwire expansion zones
– 40 wireless expansion zones
- Two low current on-board trigger outputs
- 100 Event Log viewable at system keypads with time/date stamp
- 48 system user codes assignable to either partition
- Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
- Two independent partitions plus a common partition
– Global Arming from any system keypad
– Goto function to view or operate one partition from the other
– Separate partition account numbers
- 16 output devices
– Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10® devices (when used with a 4300 Transformer)
- Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
- Supports four-wire, and up to 16 two-wire smokes
– Works with Sentrol CleanMe™ maintenance signal
- Multiple actions on output devices depending on system state
– Turns lights off when system arms
– Turns the same light on when system disarms
– Flashes same lights when system is in alarm
- Built-in phone line cut monitor with programmable delay and annunciation options
– Display on system keypads
– Trigger local sounders
– Trigger system bell
Maintenance Features
- Automatic System Load Shed
– During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries
- Dynamic Signaling
– Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio
Operation Features
- Viewable on system keypads:
– Exit countdown
– Time and date display*
– Event log*
- Auto keypad backlighting on entry
- Keyswitch arming
- Programmable macro buttons and single-button arming
- Supports a variety of wireless remote controls for single-button operation
- User Scheduling
– Automatically activates X-10 and relays at programmed times
– Latchkey reports to pagers
– Auto arm/disarm
– “User access” time windows
- Supports up to four end-user numeric pagers
- VIP Module allows system control from any touchtone phone
- Chime by zone
* Requires alpha keypad
.